Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
3.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38494437

RESUMO

OBJECTIVE: This study sought to identify periprocedural risk predictors that affect long-term prognosis in patients with chronic obstructive pulmonary disease (COPD) undergoing isolated coronary artery bypass grafting (CABG). METHODS: All consecutive 4,871 patients undergoing isolated CABG between May 2005 and June 2021 were included. Patients with and without COPD were compared for baseline demographics and preoperative characteristics. A propensity-matched analysis was used to compare the 2 groups. The primary outcome was long-term incidence of all-cause death. RESULTS: After matching, 767 patients each were included in the COPD and non-COPD groups; mean age was 71.6 and 71.4 years (P = .7), respectively; 29.3% and 32% (P = .2) were women, respectively. Intraoperatively, median (IQR) operating room time was higher in the COPD group than in the non-COPD group (5.9 [5.2-7.0] hours vs 5.8 [5.1-6.7] hours, respectively; P = .01). Postoperatively, intensive care unit stay (P = .03), hospital length of stay (P = .0004), and fresh frozen plasma transfusion units (P = .012) were higher in the COPD group than in the non-COPD group. Thirty-day mortality was not different between groups (1.3% in the COPD group vs 1% in the non-COPD group; P = .4). Median follow-up time was 4.0 years. The rate of all-cause death was higher in the COPD group than in the non-COPD group (138 patients [18.3%] vs 109 patients [14.5%], respectively; P = .042). Periprocedural risk predictors for all-cause death in patients with COPD were atrial fibrillation, diabetes, male sex, dialysis, ejection fraction less than 50%, peripheral vascular disease, and Society of Thoracic Surgeons Predicted Risk of Mortality score greater than 4%. CONCLUSION: Patients with COPD undergoing isolated CABG had a significantly higher incidence of all-cause death than those without COPD. Herein, risk predictors are provided for all-cause death in patients undergoing isolated CABG.


Assuntos
Doença da Artéria Coronariana , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Feminino , Resultado do Tratamento , Transfusão de Componentes Sanguíneos , Plasma , Ponte de Artéria Coronária/efeitos adversos , Prognóstico , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Fatores de Risco , Estudos Retrospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38532517

RESUMO

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.

5.
J Invasive Cardiol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38446024

RESUMO

OBJECTIVES: The efficacy of hybrid robotic-assisted coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR) for coronary and aortic valve disease is poorly reported. Herein, we report our experience with this hybrid approach. METHODS: Between January 2018 and June 2022, 10 (7 male, 3 female) patients with a mean age of 81 years underwent the hybrid procedure. Coronary revascularization was performed prior to TAVR with robotic-assisted left internal mammary artery-to-left anterior descending (LAD) bypass grafting for left main or proximal LAD lesions with or without multivessel disease with or without hybrid percutaneous coronary intervention (PCI). RESULTS: Five patients had left main disease, and 5 had proximal LAD disease with or without multivessel disease. All patients tolerated the robotic-assisted CABG procedure well; 9 patients were extubated in the operating room and all patients were ambulatory on postoperative day 1. Five patients underwent hybrid PCI for non-LAD lesions. TAVR was subsequently performed at intervals ranging from 3 days to 5 months after CABG. One patient with end-stage renal disease on hemodialysis required hospitalization for heart failure during the interval period. The 1-year mortality rate was 0%, and 3 patients died during late follow-up (24-43 months). CONCLUSIONS: This innovative, less invasive approach demonstrates the potential for early recovery in appropriately selected patients with complex coronary and aortic valve disease with promising mid-term outcomes.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38180892

RESUMO

OBJECTIVES: The aim of this study was to compare long-term prognosis after isolated coronary artery bypass grafting between white and black patients and to investigate risk factors for poorer outcomes among the latest. METHODS: All consecutive 4766 black and white patients undergoing isolated coronary artery bypass grafting between May 2005 and June 2021 at our institution were included. Primary outcomes were long-term incidence of all-cause death and major adverse cardiovascular and cerebrovascular events in black versus white patients. A propensity-matched analysis was used 2 compare groups. RESULTS: After matching, 459 patients were included in each black and white groups while groups were correctly balanced. The mean age was 70.4 vs 70.6 years old (P = 0.7) in black and white groups, respectively. Intraoperatively, mean operating room time and blood product transfusion, were higher in the black group while incidence of extubation in the operating room was higher in the white one. Postoperatively, hospital length of stay was higher in the black cohort. Thirty-day all-cause mortality was not different among groups. The median follow-up time was 4 years. Primary outcome of all-cause death was higher in the black versus the white, respectively. Major adverse cardiovascular and cerebrovascular events incidence was twice higher in the black compared to the white cohort (7.6% vs 3.7%, P = 0.013). Risk predictors for all-cause death and major adverse cardiovascular and cerebrovascular events in blacks were creatinine level, chronic obstructive pulmonary disease, ejection fraction <50% and preoperative atrial fibrillation. CONCLUSIONS: Racial disparities persist in a high-volume centre. Despite no preoperative difference, black minority has a higher incidence of major adverse cardiovascular and cerebrovascular events.

8.
EuroIntervention ; 20(1): 45-55, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994042

RESUMO

BACKGROUND: Patients who are not candidates for traditional coronary artery bypass grafting (CABG) and amenable only for percutaneous coronary intervention (PCI) with stents can receive the "gold standard" left internal thoracic artery (LITA) to left anterior descending artery (LAD) anastomosis through robotic-assisted CABG and PCI to non-LAD coronary targets. AIMS: We aimed to analyse clinical outcomes of robotic-assisted CABG. METHODS: A total of 2,280 consecutive patients who had undergone robotic-assisted CABG between May 2005 and June 2021 were included in our study. Robotic-assisted LITA harvest was followed by LITA-LAD manual anastomosis through a 4 cm left thoracotomy. Hybrid coronary intervention (HCR) consists of stent implantation in a non-LAD coronary artery performed within 7 days after robotic-assisted LITA-LAD. We performed a propensity-adjusted analysis comparison after dividing all robotic-assisted CABG patients into three time periods: 2005-2010, 615 patients; 2011-2016, 904 patients; and 2017-2021, 761 patients. RESULTS: The mean age increased from 64.5 years in the first time period to 65.8 years in the second time period to 68.1 years in the third (p<0.0001). Operative time was progressively reduced in the three periods (6.4; 6.2; 5.5 hours; p<0.001). The incidence of conversion to sternotomy remained similar for each period (1.8%; 1.7%; 1.5%; p=0.53). Thirty-day mortality in the three periods included 9 (1.4%), 9 (1.0%), and 7 (0.9%) patients, respectively (p=0.91), while 8 (0.3%) patients had PCI with stents in the entire group. The mean follow-up for the entire population was 4.2 years. At follow-up, the rates of all-cause death, major adverse cardiac and cerebrovascular events, non-fatal stroke, and repeat revascularisation with stents were significantly decreased from the first to the last period (pË0.0001). CONCLUSIONS: Robotic-assisted CABG and HCR provide good long-term outcomes in patients who are not candidates for conventional CABG.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
9.
Future Cardiol ; 19(14): 685-694, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38078413

RESUMO

Aim: To evaluate clinical outcomes after redo aortic valve replacement (AVR) with sutured valves, versus valve-in-valve transcatheter aortic valve replacement (ViV-TAVR), versus sutureless valves. Methods: We identified 113 consecutive patients undergoing redo AVR with either ViV-TAVR, redo-sutured and redo-sutureless valves between August 2010 to March 2020. Heart-team made the decision whether patient should undergo redo-sutureless versus ViV-TAVR, versus redo-sutured AVR. Results: Preoperatively, redo-sutured (n = 57), ViV-TAVR (n = 31) and redo-sutureless (n = 25) patients were compared. Postoperatively, after propensity-adjustment analysis, the redo surgical aortic valve replacement group had a higher incidence of new postoperative atrial fibrillation (POAF; p = 0.04) compared with redo-sutureless group. Follow-up outcomes analysis did not show differences among groups. Conclusion: Patients undergoing redo-sutureless AVR experienced a higher incidence of POAF compared with patients undergoing redo-sutured.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Prognóstico , Estenose da Valva Aórtica/cirurgia
11.
J Surg Res ; 290: 276-284, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37321148

RESUMO

INTRODUCTION: This study aimed to compare the long-term outcomes in a propensity matched population receiving total arterial grafting (TAG) and multiple arterial grafts (MAG) in addition to saphenous vein graft (SVG) following multivessel coronary artery bypass grafting requiring at least three distal anastomoses. METHODS: In this retrospective study, 655 patients from two centers met the inclusion criteria and were divided into two groups: TAG group (n = 231) and MAG + SVG group (n = 424). Propensity score matching was performed resulting in 231 pairs. RESULTS: No significant differences were observed between both groups in terms of early outcomes. Survival probabilities at 5, 10, and 15 y were 89.1% versus 94.2%, 76.2% versus 76.1%, and 66.7% versus 69.8% in the TAG and MAG + SVG groups, respectively (hazard ratio stratified on matched pairs: 0.90; 95% confidence interval [0.45-1.77]; P = 0.754). Freedom from major adverse cardiac and cerebral events (MACCE) in the matched cohort did not show any significant difference between both groups. Probabilities at 5, 10, and 15 y were 82.7% versus 85.6%, 62.2% versus 75.3%, and 48.8% versus 59.5% in the TAG and MAG + SVG groups, respectively (hazard ratio stratified on matched pairs: 1.12; 95% confidence interval [0.65-1.92]; P = 0.679). Subgroup analyses of the matched cohort showed no significant difference between TAR with three arterial conduits compared to TAR with two arterial conduits with sequential grafting and MAG + SVG in terms of long-term survival and freedom from MACCE. CONCLUSIONS: Multiple arterial revascularizations in addition to SVG may yield comparable long-term outcomes in terms of survival and freedom from MACCE compared to total arterial revascularization.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/cirurgia , Estudos Retrospectivos , Veia Safena/transplante , Resultado do Tratamento , Ponte de Artéria Coronária/métodos
12.
J Cardiovasc Dev Dis ; 10(5)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37233191

RESUMO

Objective: The goal of this manuscript is to compare clinical and echocardiographic outcomes of patients undergoing aortic valve replacement (AVR) with Perceval sutureless bioprosthesis (SU-AVR) and sutured bioprosthesis (SB). Methods: Following the PRISMA statement, data were extracted from studies published after August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural permanent pacemaker implantation, and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out), need for a second transcatheter heart valve, 30-day mortality, stroke, and echocardiographic outcomes. Results: Twenty-one studies were included in the analysis. When SU-AVR was compared to other SB, mortality ranged from 0 to 6.4% for Perceval and 0 to 5.9% for SB. Incidence of PVL (Perceval 1-19.4% vs. SB 0-1%), PPI (Perceval 2-10.7% vs. SB 1.8-8.5%), and MI (Perceval 0-7.8% vs. SB 0-4.3%) were comparable. In addition, the stroke rate was lower in the SU-AVR group when compared to SB (Perceval 0-3.7% vs. SB 1.8-7.3%). In patients with a bicuspid aortic valve, the mortality rate was 0-4% and PVL incidence was 0-2.3%. Long-term survival ranged between 96.7 and 98.6%. Valve cost analysis was lower for the Perceval valve and higher for sutured bioprosthesis. Conclusions: Compared to SB valves, Perceval bioprosthesis has proved to be a reliable prosthesis for surgical aortic valve replacement due to its non-inferior hemodynamics, implantation speed, reduced cardiopulmonary bypass time, reduced aortic cross-clamp time, and shorter length of stay.

13.
AJOG Glob Rep ; 3(2): 100183, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37229152

RESUMO

BACKGROUND: Outcomes of robotic-assisted coronary artery bypass grafting in pregnant women have not been assessed. OBJECTIVE: This study aimed to understand the importance of minimally invasive robotic-assisted coronary artery bypass grafting in pregnant woman with coronary artery disease. We describe the case of a G3P1011 woman at 19+6 weeks' gestation presenting with a non-ST myocardial infarction treated with off-pump hybrid robotic-assisted revascularization. STUDY DESIGN: This study describes the surgical approach for a pregnant woman presenting with non-ST myocardial infarction treated with hybrid robotic-assisted revascularization. RESULTS: A coronary angiography demonstrated a culprit lesion of 90% stenosis in the left anterior descending coronary artery and an 80% stenosis in the right coronary artery. Because of the high rate of complications with traditional coronary artery bypass grafting, the heart team opted for hybrid robotic-assisted revascularization and the postoperative recovery was uneventful. CONCLUSION: Robotic coronary artery bypass grafting can be the preferred surgical choice to decrease maternal and fetal mortality in patients undergoing coronary artery bypass grafting, and it is an important tool in the surgical armamentarium.

14.
Innovations (Phila) ; 18(2): 159-166, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37029651

RESUMO

OBJECTIVE: The benefits of Enhanced Recovery After Surgery (ERAS) protocols are being recognized in multiple surgical specialties, including following coronary bypass surgery to improve quality of care and decrease costs. We developed a fast-track discharge protocol for patients undergoing robotic totally endoscopic coronary bypass surgery (TECAB) to be discharged on postoperative day (POD) 1, the subjects of this study. METHODS: In a retrospective study of 720 patients undergoing robotic beating-heart TECAB over 8 years at our institution, 93 patients were selected for a fast-track POD1 discharge protocol. We compared the outcomes of this group to the remaining 627 patients who were discharged per standard protocol (non-POD1 discharge). RESULTS: The early discharge group was significantly younger, had lower Society of Thoracic Surgeons (STS) risk of mortality, and had a lower prevalence of obesity, diabetes, and chronic kidney disease. Patients discharged on POD1 were more often extubated in the operating room (56% vs 42%, P = 0.010). The readmission rate for the early discharge group was 3.2%, which was similar to the readmission rate of 6.7% for the standard discharge protocol group (P = 0.329). Time to return to work was shorter in the early discharge group, although it did not quite reach statistical significance (12 vs 18 days, P = 0.051). There was no difference in midterm cardiac mortality. CONCLUSIONS: Early discharge on POD1 after robotic TECAB is appropriate in selected patients and is associated with low readmission rates and a trend towards earlier return to work. Patients suitable for this "ultrafast-track" approach were more likely to be younger, have lower STS risk, and fewer comorbidities.


Assuntos
Doença da Artéria Coronariana , Recuperação Pós-Cirúrgica Melhorada , Procedimentos Cirúrgicos Robóticos , Humanos , Alta do Paciente , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Ponte de Artéria Coronária/métodos , Endoscopia/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia
15.
Cardiovasc Revasc Med ; 55: 10-19, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37062610

RESUMO

BACKGROUND: The aim of this study is to identify risk predictors that impact long-term prognosis in patients undergoing isolated aortic valve replacement (AVR) with Perceval sutureless bioprosthesis aortic valve implantation. METHODS: From 2013 to 2020, 101 consecutive participants who underwent isolated AVR with the Perceval sutureless bioprosthesis were included. Primary endpoint was analysis of all-cause mortality. We performed a propensity-adjusted analysis of patients undergoing redo sutureless vs redo sutured AVR to understand the impact of sutureless valves in redo operations. RESULTS: Pre-operative characteristics included a mean age of 71.2-years, mean EuroScore II of 3.51 (±4.48), mean body mass index of 30.2 (±6.8). Mean follow-up was 1.5 years. Intraoperatively, mean cardiopulmonary bypass time and aortic cross-clamp time were 65 ± 29.6 and 47.3 ± 21.3 min, respectively. Valve redeployment was necessary in 9.9 % of cases and there was one intraoperative death. There were two hospital deaths (including the operative death) while only one was cardiac related. Postoperatively, mean ejection fraction was 55.5 % (±4.1 %), mean effective orifice was 1.5 (±0.3) cm2, and mean transvalvular gradient was 14.7 (±4) mmHg. At 7-years follow-up, 87.9 % of patients were alive. Risk predictors for all-cause death were female sex and left ventricular diastolic dysfunction (LVDD) grade ≥ 2. After matching, aortic cross-clamp time, inotrope use, blood product transfusions, respiratory failure, and post-operative arrhythmias were higher in the redo sutured group compared to the sutureless redo group. CONCLUSIONS: Sutureless aortic valve implantations have good clinical outcomes. Risk predictors for all-cause death included female sex and LVDD grade ≥ 2.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Disfunção Ventricular Esquerda , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Desenho de Prótese , Prognóstico , Estudos Retrospectivos
16.
Innovations (Phila) ; 18(2): 193-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36872581

RESUMO

In this article, we focus on the important role of robot-assisted coronary surgery by reporting the successful case of a morbidly obese male (body mass index = 58 kg/m2) who presented to our center with severe coronary disease. A 54-year-old morbidly obese male presented with acute chest pain and was diagnosed with coronary artery disease. The culprit lesion was the left anterior descending (LAD) coronary artery. A percutaneous coronary intervention angiography attempted in a university hospital was not successful. Our heart team chose a hybrid robot-assisted revascularization (HCR) strategy based on the patient's body size. The patient underwent left internal thoracic mammary artery to LAD bypass with uneventful postoperative recovery. Robotic HCR is a valuable strategy in morbidly obese patients undergoing coronary artery bypass grafting.


Assuntos
Doença da Artéria Coronariana , Obesidade Mórbida , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia
17.
JACC Cardiovasc Imaging ; 16(3): 298-310, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36648055

RESUMO

BACKGROUND: It remains controversial whether prosthesis-patient mismatch (PPM) (in general considered moderate if indexed effective orifice area is 0.65-0.85 cm2/m2 and severe when <0.65 cm2/m2) affects the outcomes after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The purpose of this study is to evaluate the time-varying effects and association of PPM with the risk of overall mortality. METHODS: Study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of studies published by December 30, 2021. RESULTS: In total, 23 studies met our eligibility criteria and included a total of 81,969 patients included in the Kaplan-Meier curves (19,612 with PPM and 62,357 without PPM). Patients with moderate/severe PPM had a significantly higher risk of mortality compared with those without PPM (HR: 1.09 [95% CI: 1.04-1.14]; P < 0.001). In the first 30 months after the procedure, mortality rates were significantly higher in the moderate/severe PPM group (HR: 1.1 [95% CI: 1.05-1.16]; P < 0.001). In contrast, the landmark analysis beyond 30 months yielded a reversal of the HR (0.83 [95% CI: 0.68-1.01]; P = 0.064), but without statistical significance. In the sensitivity analysis, although the authors observed that severe PPM showed higher risk of mortality in comparison with no PPM (HR: 1.25 [95% CI: 1.16-1.36]; P < 0.001), they did not observe a statistically significant difference for mortality between moderate PPM and no PPM (HR: 1.03 [95% CI: 0.96-1.10]; P = 0.398). CONCLUSIONS: Severe PPM, but not moderate PPM, was associated with higher risk of mortality following TAVR. These results provide support to implementation of preventive strategies to avoid severe PPM following TAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Valor Preditivo dos Testes , Fatores de Risco
18.
Braz J Cardiovasc Surg ; 38(3): 407-410, 2023 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-36692050

RESUMO

In the setting of minimally invasive and robotic-assisted intracardiac procedures, de-airing requires further technical considerations due to limited access to the pericardial space and the subsequent difficulty of directly manipulating the heart. We summarize the technical steps for de-airing according to different cannulation strategies for minimally invasive and robotic-assisted intracardiac procedures.


Assuntos
Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Coração
19.
Artigo em Inglês | MEDLINE | ID: mdl-36632858

RESUMO

Patients in hemodialysis with an arm arteriovenous fistula undergoing coronary artery bypass grafting (CABG) with an internal thoracic artery have been reported to suffer from coronary-subclavian steal (CSS) during dialysis session. However, its occurrence is still debated. A systematic literature review was performed to identify all studies investigating the occurrence of a CSS event in this subset of patients. The primary endpoint was the analysis of CSS and the following early and late survival outcomes. Independent determinants of CSS and the impact of the distance between the arteriovenous fistula (upper arm vs forearm) and the ipsilateral internal thoracic artery graft on CSS events and mortality were studied. Early and late survival outcomes were analyzed by comparing ipsilateral versus contralateral arteriovenous fistula. Of the 1,383 retrieved articles, 10 were included (n = 643 patients). The pooled event rate of CSS was 6.46% [95%CI=2.10-18.15], while of symptomatic CSS incidence was 3.99% [95%CI=0.95-15.25]. No survival differences were noted when comparing ipsilateral to contralateral arteriovenous fistula-internal thoracic artery combinations. On meta-regression, the upper arm was associated with more CSS events, while the forearm to lower late mortality rates. Independently from arteriovenous fistula-internal thoracic artery combination, CSS was not associated to higher mortality rates. Particular attention is warranted when selecting the type of conduits for CABG in patients with an arteriovenous fistula or if highly expected to need one in the near future after surgery. A contralateral arteriovenous fistula-internal thoracic artery combination is preferable. If this is not possible, a forearm arteriovenous fistula position should be preferred.

20.
Trends Cardiovasc Med ; 33(4): 225-239, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35051591

RESUMO

Mitral valve repair (MVr) restores leaflets coaptation while preserving the patient's own valve. The two main techniques are: (a) chordal replacement ("respect approach"), whereby artificial neochordae are used to resuspend prolapsed segments of the affected leaflet - and (b) leaflet resection ("resect approach"), whereby diseased leaflet segment is resected, and the remaining segments are sutured together. Both techniques of MVr are associated with better long-term results, fewer valve-related complications and lower mortality when compared with mitral valve replacement (MVR). They also restore quality of life and improve survival to rates equivalent to those of the general population. We performed a meta-analysis to pool data of clinical studies that compared outcomes of MVr stratified by the surgical technique. Seventeen studies accounting for 6,046 patients fulfilled our eligibility criteria. The "respect approach" outperformed the "resect approach" with lower permanent pacemaker implantation rates and lower mean gradients. Despite any possible advantages of one technique over the other, which approach is best for each patient must be decided on a case-by-case basis and more long-term follow-up data are warranted.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Qualidade de Vida , Respeito , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...